Make your own free website on Tripod.com
K2/100 sn 1538 with both suppies connected. K2 on it's right side with the KPA100 laying next to it on the bench. Dummy load connected through a couple pieces of RG58 and two switches. Works similar on a tuned antenna. I only have one DMM so the diferent readings are taken on different tests. However they repeat fairly closely when the power is set the same.
This may an obtuse way to do this, but I'm trying to understand how it works.
Power Control 5 Watts
Freq VPWR K2 IND PWR Ext Watt Meter VRFDET
3992 .866 5.2 ~5 1.924
7285 .748 5.6 ~5 1.729
10125 .765 5.5 ~5 1.643
14250 .986 5.3 ~5 1.588
18134 .939 5.3 ~5 1.585
21320 .992 5.5 ~5 1.730
24950 1.168 5.8 ~5 2.106
28385 1.024 5.7 ~5 1.226
POWER SET TO 15 WATTS
3992 .653 13 25/30 1.6/1.78
7285 .618 14 25/30 1.52/1.66
10125 .60 14 18 1.2/1.4
14250 .995 14 30 1.7/1.8
18134 1.00 14 70 2.788
21320 4.83 rail? 14 75 2.995
24950 .92 14 30/35 1.8/2.0
28385 1.38 unstable 15/18 1.3/1.4
POWER SET TO 50 WATTS
3992 .780 51 75 2.8
7285 .76 51 65 2.54
10125 .729 51 50 2.21
14250 1.169 51 65 2.86
18134 3.7 41 98 3.334
21320 4.82 rail? 14 75 2.975
24950 unstable unstable 60 2.648
28385 1.72 49 40 2.28
home